One device per circuit, from £625

RCBO Consumer Units in Sussex

If your fuse board trips again and again and takes half the house down with it, the fix is not another hopeful reset, it is a better board. A full RCBO consumer unit gives every circuit its own combined breaker and 30mA RCD, so one fault trips one circuit and everything else stays on. It is the board we recommend for most Sussex homes, fitted in a day and certified under Part P.

Full RCBO consumer unit fitted in a Sussex home, one protective device per circuit

A full RCBO board: one protective device per circuit

The service

What is an RCBO? One breaker, two jobs

An RCBO, short for residual current breaker with overcurrent protection, does two jobs in one slim device. It is an MCB, tripping when a circuit overloads or short circuits, and it is a 30mA RCD, disconnecting in milliseconds when current leaks to earth through a damaged cable, a wet fitting or a person. Fit one on every circuit and you have a full RCBO board.

Compare that with the dual RCD boards fitted in most Sussex homes over the last fifteen years. Two RCDs each guard a bank of circuits, so when a fault appears on one circuit, everything sharing that RCD goes dark with it. That is how a tripped shower in a typical Sussex semi quietly defrosts the freezer in the garage, and why a board that trips like that can swallow a whole evening of unplugging before you find the cause.

An RCBO consumer unit upgrade ends all of that. One fault trips one circuit, the tripped device points straight at the problem, and the other circuits carry on as if nothing happened. Of the 2,400+ boards we have fitted since 2009, from Victorian terraces in the coastal towns to interwar semis along the coast, full RCBO boards are the ones we recommend most often.

  • Guide priceFull RCBO from £625 including surge protection and certification
  • Time on site4 to 6 hours, power off for around 4 to 5 of them
  • BookingInstall slots 3 to 5 working days out, quotes same day from a photo
  • CertificationEIC emailed within 48 hours, Part P notified to Building Control
  • Guarantee6 years on workmanship, £5m public liability

Board tripping all the time?

Text a photo of your board for a same day fixed price on an RCBO upgrade.

Send a photo
Job photo

An RCBO consumer unit in Sussex

One photo from this kind of job in Sussex, showing a full RCBO board with one device per circuit, fitted and labelled.

Safety aspects

The safety case for one device per circuit

An RCBO board is not a luxury version of the same protection, it changes how the whole installation behaves under fault. Here is what one device per circuit actually does for a Sussex home.

  1. 30mA shock protection on every circuit Each RCBO disconnects in under 40 milliseconds when current leaks to earth, fast enough to prevent a fatal electric shock. No circuit sits outside that protection, upstairs lighting and the loft included.
  2. Faults stay local A fault trips its own circuit and nothing else. The freezer, fridge, burglar alarm, router and home office keep running, and anyone relying on powered medical equipment keeps their supply while the faulty circuit waits for attention.
  3. Faster, safer fault finding When a shared RCD drops, six circuits go dark and the fault could be on any of them, so people reset again and again onto a live fault while they guess. An RCBO names the circuit the moment it trips, so the fault is found and isolated safely.
  4. Nuisance tripping stops bad habits When a board trips constantly, people prop switches on, bypass devices or leave the RCD off entirely, and the protection quietly disappears. Spreading earth leakage across individual RCBOs removes the nuisance trips, so the safety devices stay in service.
  5. Selectivity designed, not assumed We design the board so devices operate in the right order: the circuit device trips first and the main switch stays closed. High leakage loads such as EV chargers and long outdoor runs to garden offices and outbuildings get their own properly rated devices.
  6. Proved on handover Every RCBO is test-buttoned and trip-time tested with a calibrated instrument by our Level 3 qualified testing engineers, and the measured times are recorded on your Electrical Installation Certificate. You watch the protection work before we leave.
RCBO vs dual RCD

Same regulations, very different day to day

  • One fault trips one circuit, never half the house
  • Freezer, fridge, alarm and router stay live during a fault elsewhere
  • The tripped RCBO identifies the faulty circuit instantly
  • Earth leakage is spread across many devices, so nuisance tripping largely disappears
  • Home offices and medical equipment keep their supply
  • Around £200 more than a dual RCD board, roughly £10 a year over its life

Both board types meet the 18th Edition, and for a tight budget a dual RCD board is still safe, compliant protection. But in the Regency and Victorian houses converted into flats along the Sussex coast, where one landlord board might feed a shower, a kitchen and a home office, the difference between the two is the difference between a thirty second reset and an evening in the dark. That is why RCBO is our default recommendation.

Board options

Sized for your home

If you are pricing an RCBO consumer unit upgrade, Sussex homes usually fall into one of three sizes.

Full RCBO, 8 ways

from £625

Right for flats and smaller conversions anywhere in Sussex, including the Regency and Victorian conversions in the coastal towns. Every circuit gets its own RCBO, with a Type 2 surge protection device included as standard.

Full RCBO, 10 to 12 ways

from £695

The usual fit for three bed houses, from Victorian and Edwardian terraces in Worthing, Eastbourne and Hastings to interwar semis and 1950s to 1970s estates. Room for cooker, shower and EV circuits, each one independently protected, SPD included.

Full RCBO, 14 to 16 ways

from £795

For four and five bed homes with garden offices, lofts and outbuildings, from new build estates around Burgess Hill, Horsham and Chichester to farmhouses in the Weald and on the Downs. Spare ways left for whatever comes next, SPD included.

Tripping problems

When a fuse box keeps tripping, listen to it

However you describe a board that keeps tripping, the message is the same: a protective device is doing its job and something is leaning on it. Boards trip for three broad reasons. Overload, where a circuit is asked to carry more current than its rating. Short circuit, where line and neutral touch. And earth leakage, where current escapes to earth through damp, damaged insulation or a failing appliance, and an RCD steps in to disconnect it. An RCBO fusebox upgrade tackles that third kind at the board itself, one circuit at a time, instead of letting half the house share the consequences.

Modern homes make that third cause worse on shared boards. Every appliance leaks a tiny, harmless current to earth, and on a dual RCD board those small leaks add up on one device. Add a wet winter and a garden socket and the RCD keeps tripping even though no single item is obviously at fault. A fuse box tripping after upgrade is usually a version of the same story: the new board is not faulty, it is measuring earth leakage the old fuses never could, and it is pointing at a circuit that needs attention.

This is where per circuit protection earns its keep. Every board we fit is an 18th Edition consumer unit, and on a full RCBO board leakage no longer accumulates on a shared device. Nuisance trips largely disappear, and the trips that remain identify a real fault on a named circuit.

Patterns we see

Tripping patterns, decoded

  • One RCD trips at random and takes half the house: accumulated earth leakage on a shared device
  • The main switch keeps tripping: heavy leakage reaching a whole house RCD, or a device wearing out
  • The fuse box won't reset even with everything unplugged: a live fault in the fixed wiring
  • Trips in wet weather: moisture in a garden socket, outside light or EV charger
  • Trips when the shower or kettle goes on: an overloaded circuit or a failing heating element
  • Trips at the same time each day: a timed load, often an immersion heater, breaking down

Recognise one of these? Text a photo of your board and we will say honestly whether it needs a repair or a new board, with a fixed price either way.

How it works

Your RCBO upgrade, start to finish

Step
01

Send a photo, get a fixed price

Text a photo of your current board with your postcode and we price the RCBO upgrade the same day. The phone is answered 8am to 8pm, 7 days, anywhere in Sussex.

Step
02

Booked within the week

Most installations are scheduled 3 to 5 working days out. We confirm the arrival window the night before, and can add a full EICR for £99 while we are there.

Step
03

Fitted and tested in a day

Old board out, RCBO board in, typically 4 to 6 hours on site with power off for 4 to 5 of them. Every RCBO is trip-time tested with a calibrated instrument before handover.

Step
04

Certified and notified

Your Electrical Installation Certificate arrives by email within 48 hours and we notify your local council's Building Control under Part P. Backed by our 6 year workmanship guarantee.

Straight answers

RCBO consumer unit FAQs

For most homes, yes. The difference is around £200: a dual RCD board starts at £425 and a full RCBO fuse board at £625. That buys you a board where one fault trips one circuit instead of half the house, fault finding takes minutes rather than an evening of unplugging, and the freezer keeps running whatever the shower does. Spread over the twenty year life of a consumer unit it is a small premium, which is why RCBO boards are what we recommend and fit most often across Sussex.

Sometimes. If your board is a reasonably modern make and the manufacturer still produces compatible RCBOs, we can swap the existing breakers for RCBOs on a like for like basis. Mixing brands inside one enclosure is not acceptable, because devices are only tested and warranted in their own manufacturer's board. In practice, once an older board is opened up and the parts are priced, a full RCBO consumer unit upgrade with new tails, a Type 2 SPD and a fresh certificate is often the better value, and we will price both options honestly so you can decide.

Rain tripping is almost always moisture getting into something outside: a garden socket, outdoor lighting, a shed feed run along the fence, or a worn seal on an EV charger. Water lets a small current leak to earth, and on a dual RCD board that leakage lands on an RCD shared by several circuits, so the trip looks random. With RCBOs the tripped device names the guilty circuit immediately. Either way the leak needs finding and fixing: a fuse board that trips in wet weather is warning you about a real fault, and we trace and repair them across Sussex.

Yes, that is exactly the problem they solve. On a dual RCD board the freezer usually shares an RCD with several other circuits, so a faulty kettle or a tripped shower can silently kill the freezer while you are at work or away for the weekend. With a full RCBO board the freezer circuit has its own device, and nothing that happens elsewhere in the house will disconnect it. For anyone in Sussex who has come home to a defrosted freezer and a puddle, this alone tends to justify the upgrade.

Type A describes what the RCD element inside each breaker can detect. Older Type AC devices can be blinded by the small DC components that modern electronics, induction hobs, EV chargers and solar inverters put back into the wiring, so they may fail to trip when it matters. A Type A RCBO consumer unit detects those pulsating DC currents as well as normal AC faults. Every RCBO board we fit across Sussex uses Type A devices as standard, in line with current wiring regulations.

It means the device is holding against a live fault: the earth leak is still there, so the RCD trips the instant you close it. Unplug everything on the affected circuits and try again. If it holds, one appliance is faulty, so plug things back in one at a time to find it. If the fuse box won't reset with everything unplugged, the fault is in the fixed wiring and needs testing, not repeated resetting. In an emergency we aim to reach you the same day anywhere in Sussex, and within 45 to 90 minutes in Brighton & Hove.

On many boards the main switch is actually a whole house RCD, so heavy earth leakage anywhere in the installation can drop everything at once. It can also point to a loose main connection or a device that is wearing out, and both of those generate heat where you do not want it. Treat it as urgent rather than resetting it over and over. A full RCBO board removes the shared device entirely, so a single fault can no longer switch off the whole house.

Yes, on the day. A dual RCD consumer unit replacement starts at £425 for 6 ways or £495 for 10, against £625 for a full RCBO board at 8 ways. Both meet the 18th Edition, and both include a Type 2 SPD, full testing, an Electrical Installation Certificate and Part P notification. The difference is what happens under fault: a dual RCD board shares protection across banks of circuits, so one fault darkens several. For around £200 more, every circuit stands alone.

RCBO boards near you

RCBO consumer units fitted across Sussex

Full RCBO boards go in at the same fixed prices in every place listed here. Find your town or village for its own local page.

826 places

Villages, hamlets and neighbourhoods 775 places, by council area

Adur 5 places
Arun 57 places
Chichester District 173 places
Crawley 18 places
Horsham District 120 places
Mid Sussex 57 places
Worthing 1 place
Lewes District 56 places
Rother 103 places
Wealden 185 places
Fixed price today

End the tripping lottery this week

Call for a straight answer on RCBO boards, or send a photo of your fuse box and get a fixed price back the same day, anywhere in Sussex.