Fuse Box Replacement in Bewbush
Bewbush is a Crawley neighbourhood built from the 1970s onwards, about 2.6 km west of the town centre in the RH11 postcode. One fixed price covers swapping a worn fuse box, whether you live in the house or let it out, along with testing every circuit in the property and emailing the certificate within 48 hours.
- Part P registered installers
- Fitted and certified in a day
- Surge protection as standard
- Fixed prices, no surprises
- 17+ YearsEst. 2009 in Brighton & Hove
- 6 Year GuaranteeWorkmanship, every board
- Specialist TeamDirectly employed installers
- Free QuotationSurvey or photo, no call out fee
- 2,400+Boards replaced since 2009
Fuse box services for Bewbush
RCBO Consumer Units
AFDD Consumer Units
Surge Protection
Fuse Box Relocation
Landlord Fuse Box Upgrades
EICR Testing
Transparent Pricing
Free Fixed Quotes

Decades old homes, boards of every vintage
Bewbush came in Crawley's later wave of new town building, mostly terraced and semi detached homes with some flats. After several decades the consumer units vary widely: some are early boards with no RCD protection at all, while others were swapped during a kitchen or bathroom refit without every circuit being brought up to date.
Most terraced and semi detached layouts fit comfortably on a dual RCD board, priced from £425, or £495 with 10 ways. Where you want each circuit to stand alone, full RCBO protection starting at £625 is the better choice. Surge protection is included either way.
- Boards without RCDs replaced
- Part upgraded boards finished
- Terraces, semis and flats
- Surge protection included

Rented homes, reports and repairs
Owned and rented homes sit side by side in Bewbush, and under the 2020 private rented sector regulations a landlord in England must have the electrics inspected and tested no more than five years apart, handing the tenants a copy of the report. When an EICR finds the old fuse box unsatisfactory, the remedial work must be done within 28 days.
We can replace the board and carry out the EICR on the same visit. The report costs £99 when booked with any board change, against £175 to £350 on its own, or from £350 for an HMO. Tenants can usually stay in, with power back within four to six hours.
- Five yearly EICRs
- Remedial work within 28 days
- EICR £99 with a board
- Tenants can stay home
Into west Crawley from the A23
Getting to Bewbush is easy for us, with the A23 bringing us into Crawley from the south. Landlords can book around a tenant's diary, and owners around their own. Should the old board give up and leave the property without power, phone us any day of the week, as a same day attendance is what we aim for.
Bewbush at a glance
- AreaCrawley borough, unparished
- CouncilCrawley Borough Council
- PostcodeRH11
- Town centreCrawley, 2.6 km east
- Typical homes1970s onwards terraces, semis and flats
A new consumer unit, fitted in a day
- 01The first hour
Protect, isolate, strip out
- 02Hours two to four
Fit and terminate the new board
- 03Hour five
Test every single circuit
- 04The final hour
Energise, label, walk through
Not sure how many ways your board needs?
Text a photo of your current fuse box to 0333 360 8691 and we will tell you, with a fixed price, today.
Fixed prices in Bewbush
Dual RCD board
6 way, from£425- Ideal for 1 to 2 bed flats
- 10 way from £495
- Surge protection included
High integrity
12 way, from£575- 3 to 4 bed houses
- Critical circuits isolated
- Surge protection included
Full RCBO board
8 way, from£625- 10 to 12 way from £695
- 14 to 16 way from £795
- Our recommendation
RCBO + AFDD
10 way, from£1,095- 14 way from £1,295
- HMOs & period terraces
- Selected circuits from £845
No travel charge to Bewbush. Full breakdown on the pricing page.
Asked in Bewbush
Call for a straight answer from an installer, not a call centre.
Call 0333 360 8691Yes, and it saves money. The EICR costs £99 when booked with a board change, compared with £175 to £350 as a separate job. We replace the board, test the whole property and issue both the Electrical Installation Certificate and the condition report, so you have what your tenants and any letting agent need.
It can be either. A kettle, washing machine or outdoor socket with a small fault will trip an RCD, and on an older shared RCD board that can cut power to several rooms. We test circuit by circuit to find the cause. If the board itself is faulty or poorly arranged, replacing it is the lasting fix.
No. If your tenant is happy to let us in, we agree the plan with you by phone and with them on the day. We email you the fixed quote, the certificate and the test results, so you have everything you need without making the trip yourself.
Also covering places near Bewbush
Book your Bewbush fuse box replacement
Own or let a home in Bewbush? The price is fixed from a single snapshot of the fuse box sent to 0333 360 8691, with the EICR available for £99 if you need one.
- Call, 8am to 8pm0333 360 8691
- CoverageBewbush: RH11