Fuse Box Replacement in Poling
North of Rustington, with a parish of its own, the small rural village of Poling feels closer to the farmland around Arundel than to the seafront. Homes here are spread out, and we replace their fuse boxes with full attention to rural supplies and earthing.
- Part P registered installers
- Fitted and certified in a day
- Surge protection as standard
- Fixed prices, no surprises
- 17+ YearsEst. 2009 in Brighton & Hove
- 6 Year GuaranteeWorkmanship, every board
- Specialist TeamDirectly employed installers
- Free QuotationSurvey or photo, no call out fee
- 2,400+Boards replaced since 2009
Fuse box services for Poling
RCBO Consumer Units
AFDD Consumer Units
Surge Protection
Fuse Box Relocation
Landlord Fuse Box Upgrades
EICR Testing
Transparent Pricing
Free Fixed Quotes

Older country homes with outbuildings
Housing in Poling is largely older cottages and farmhouses, with some newer homes among them. Many have been extended over the generations, and the electrics often include a supply out to a barn, workshop or stable, sometimes run as an overhead or buried cable that nobody has tested in years. Those outbuilding circuits matter as much as the board in the house.
We test any outbuilding supply as part of the board change, checking the cable, its protection and the earthing at the far end. Where an outbuilding needs its own small board, we explain why. A modest cottage can often manage with six ways of dual RCD protection at £425, but a farmhouse with several outbuildings is usually better off with RCBOs.
- Barn and workshop supplies tested
- Outbuilding boards checked
- Extended farmhouses re-protected
- RCBO boards from £625

Rural supplies need a different earth
Out in the countryside, many homes are fed by overhead lines on poles, and the network may not provide an earth at all. The house then relies on an earth rod sunk into the ground close by, which is known as a TT arrangement. RCD protection is essential on these supplies, because without it a fault may not draw enough current to operate a fuse or breaker.
Whenever we change a board on a TT supply, we measure how well the rod is performing, inspect it and its clamp, and lay out the new board to suit, usually with a time delayed main RCD or RCBOs on every circuit. If there is no rod, or the reading is poor, you hear about it before any work begins.
- Earth rod tested on every visit
- Boards arranged for TT supplies
- Time delayed main RCD where needed
- Supply entry checked
Reaching Poling from the coast or the A27
Poling is reached from the A27 or up from the coast through Rustington. Rural addresses can be hard to find, so a map pin or directions to the right entrance is welcome when you book. No travel charge applies. If it is an emergency, phone us on any day, and we will be looking to reach you that same day.
Poling at a glance
- ParishPoling
- CouncilArun District Council
- PostcodeBN18
- Nearest townRustington, 2.6 km south
- Supply we expectOften overhead, TT earthing possible
A new consumer unit, fitted in a day
- 01The first hour
Protect, isolate, strip out
- 02Hours two to four
Fit and terminate the new board
- 03Hour five
Test every single circuit
- 04The final hour
Energise, label, walk through
Not sure how many ways your board needs?
Text a photo of your current fuse box to 0333 360 8691 and we will tell you, with a fixed price, today.
Fixed prices in Poling
Dual RCD board
6 way, from£425- Ideal for 1 to 2 bed flats
- 10 way from £495
- Surge protection included
High integrity
12 way, from£575- 3 to 4 bed houses
- Critical circuits isolated
- Surge protection included
Full RCBO board
8 way, from£625- 10 to 12 way from £695
- 14 to 16 way from £795
- Our recommendation
RCBO + AFDD
10 way, from£1,095- 14 way from £1,295
- HMOs & period terraces
- Selected circuits from £845
No travel charge to Poling. Full breakdown on the pricing page.
Asked in Poling
Call for a straight answer from an installer, not a call centre.
Call 0333 360 8691Follow the thick earth cable from your board. Where it ends at the supplier's sealed equipment by the meter, the network gives you an earth. Where it goes out through the wall to a rod in the garden, sometimes under a small inspection cover, the supply is probably TT. A photo of the meter position lets us confirm it before quoting.
Yes. That board is tested alongside the house, and you get a straight answer on whether it is safe. If the outbuilding board is old or unsuitable, we can price a replacement from your photos. The cable between the house and the outbuilding also gets checked, since buried and overhead runs on rural properties can deteriorate without anyone noticing.
Usually, yes. A heat pump needs a dedicated circuit and sometimes more capacity than an older board can offer. Fitting the new board first, with ways set aside for the heat pump and its controls, saves a second visit later. Mention it when you send photos and we will size the board accordingly.
Also covering places near Poling
Book your Poling fuse box replacement
Photograph your board, your meter and any outbuilding supply, then text the pictures to 0333 360 8691. You will be sent a fixed quote for the Poling job by return.
- Call, 8am to 8pm0333 360 8691
- CoveragePoling: BN18