Fuse Box Replacement in North Chailey
North Chailey lies by the crossroads of the A272 and the A275, south east of Haywards Heath. If your board trips for no obvious reason, or takes half the house down with it, we can find what is causing it and replace the board at a fixed price.
- Part P registered installers
- Fitted and certified in a day
- Surge protection as standard
- Fixed prices, no surprises
- 17+ YearsEst. 2009 in Brighton & Hove
- 6 Year GuaranteeWorkmanship, every board
- Specialist TeamDirectly employed installers
- Free QuotationSurvey or photo, no call out fee
- 2,400+Boards replaced since 2009
Fuse box services for North Chailey
RCBO Consumer Units
AFDD Consumer Units
Surge Protection
Fuse Box Relocation
Landlord Fuse Box Upgrades
EICR Testing
Transparent Pricing
Free Fixed Quotes

Split load units and their weak spot
Alongside older properties, villages like North Chailey include houses from the later twentieth century, and many homes built or rewired in that period were given a split load consumer unit. One RCD protects some circuits, usually the sockets, while others such as lighting have none. It was a real improvement on fuse wire, but by today's standards it leaves gaps.
The usual trouble is that one RCD carries the combined leakage of every circuit behind it, so a small fault anywhere can trip them all together. A new unit closes the gaps, giving lighting and every other circuit RCD protection, and spreads the circuits across separate devices.
- Split load boards replaced
- Lighting circuits protected too
- Leakage spread across devices
- Old fuses and breakers removed

Finding the reason a board keeps tripping
A board that trips at random is telling you something, though not always what you think. Common causes include moisture in an outdoor socket or light, a failing appliance, the built up leakage of many electronic devices on one RCD, or a damaged cable. Swapping the board without finding the cause just moves the problem somewhere else.
We test first, circuit by circuit, to locate the fault, then recommend the right board. A full RCBO unit from £625 for 8 ways gives each circuit its own protection, so if something does trip, only that circuit goes off and the culprit is easy to trace.
- Faults located before replacing
- Outdoor fittings checked for damp
- Each circuit on its own RCBO
- Essential circuits kept separate
North Chailey call outs
From our Brighton base it is a manageable trip whichever way the traffic sends us, across country from the A23 or up from Lewes. Send a few pictures of your board and the price we give is fixed. When the power trips off and refuses to stay on, ring, and we will help that day if it can be done.
North Chailey at a glance
- ParishChailey
- CouncilLewes District Council
- PostcodeBN8
- Nearest townHaywards Heath, 6.5 km to the north west
- Boards we expectSplit load and early RCD units
A new consumer unit, fitted in a day
- 01The first hour
Protect, isolate, strip out
- 02Hours two to four
Fit and terminate the new board
- 03Hour five
Test every single circuit
- 04The final hour
Energise, label, walk through
Not sure how many ways your board needs?
Text a photo of your current fuse box to 0333 360 8691 and we will tell you, with a fixed price, today.
Fixed prices in North Chailey
Dual RCD board
6 way, from£425- Ideal for 1 to 2 bed flats
- 10 way from £495
- Surge protection included
High integrity
12 way, from£575- 3 to 4 bed houses
- Critical circuits isolated
- Surge protection included
Full RCBO board
8 way, from£625- 10 to 12 way from £695
- 14 to 16 way from £795
- Our recommendation
RCBO + AFDD
10 way, from£1,095- 14 way from £1,295
- HMOs & period terraces
- Selected circuits from £845
No travel charge to North Chailey. Full breakdown on the pricing page.
Asked in North Chailey
Call for a straight answer from an installer, not a call centre.
Call 0333 360 8691Water getting into an outdoor socket, a garden light, an external cable joint or a garage supply is the usual reason. Moisture creates a small leakage path to earth, and the RCD does exactly what it should. We test the outdoor circuits, find the wet fitting and replace or reseal it, then put that circuit on its own protection.
It may be working, but a board like that was usually extended in stages, and the older half normally has no RCD protection at all. We would recommend a single new unit. Six ways on two RCDs start at £425, and from £625 every circuit can have separate protection on a full RCBO board.
Fitting usually takes between four and six hours, with the supply off for much of that while the circuits are disconnected and then reconnected. We confirm the start time when we book. Keep fridges and freezers closed and they will normally be fine, and we check they are running again before we leave.
Also covering places near North Chailey
Book your North Chailey fuse box replacement
Text board photos on 0333 360 8691, together with a note of how often the board trips. You get back a fixed figure for the whole job.
- Call, 8am to 8pm0333 360 8691
- CoverageNorth Chailey: BN8