Fuse Box Replacement in Goose Green
Many homes in rural Thakeham parish, Goose Green among them, are moving away from oil or LPG heating. The hamlet lies north east of Storrington, and the old fuse boxes we take out here are replaced with boards ready for those heavier electrical loads.
- Part P registered installers
- Fitted and certified in a day
- Surge protection as standard
- Fixed prices, no surprises
- 17+ YearsEst. 2009 in Brighton & Hove
- 6 Year GuaranteeWorkmanship, every board
- Specialist TeamDirectly employed installers
- Free QuotationSurvey or photo, no call out fee
- 2,400+Boards replaced since 2009
Fuse box services for Goose Green
RCBO Consumer Units
AFDD Consumer Units
Surge Protection
Fuse Box Relocation
Landlord Fuse Box Upgrades
EICR Testing
Transparent Pricing
Free Fixed Quotes

Homes heated without mains gas
If your home in Goose Green is heated by storage heaters, an immersion on a cheap rate, oil or LPG, there is a good chance the electrics show it. We often find a second small board or a row of switched fuses beside a two rate meter, feeding off peak circuits that were added long after the original fuse box.
A new consumer unit can bring those circuits together, with the off peak supply kept separate where your meter arrangement needs it. We check the cable to each heater and the immersion, because these long running loads show up tired connections faster than anything else in the house.
- Off peak circuits tidied up
- Storage heater cables checked
- Immersion circuit tested
- Two rate metering respected

Swapping oil or LPG for a heat pump
Many rural households are looking at replacing an oil or LPG boiler with an air source heat pump. The heat pump needs its own protected circuit, the main fuse has to cope with the extra demand, and an ageing board with no spare ways usually holds the whole project up until it is dealt with.
We fit a board with ways set aside for the heat pump and its controls, so the heating installer can connect without a second board change. If the incoming supply looks too small, we tell you before you commit, so the request to UK Power Networks can go in early.
- Ways reserved for heat pump circuits
- Main fuse capacity checked
- Supply upgrade flagged early
- Full RCBO board from £625
Directions we take to Goose Green
We travel via the A27 and the A283 to Storrington, then north through Thakeham parish on the lanes to the hamlet. Coming via the A24 and Ashington works well too. Travel is free wherever you are. Text over some board photos and the price is fixed; if the power has gone, phone us, and getting there the same day is what we try for.
Goose Green (Thakeham) at a glance
- ParishThakeham
- CouncilHorsham District Council
- PostcodeRH20
- Nearest townStorrington, 5.2 km south west
- Worth planning forHeat pump circuits
A new consumer unit, fitted in a day
- 01The first hour
Protect, isolate, strip out
- 02Hours two to four
Fit and terminate the new board
- 03Hour five
Test every single circuit
- 04The final hour
Energise, label, walk through
Not sure how many ways your board needs?
Text a photo of your current fuse box to 0333 360 8691 and we will tell you, with a fixed price, today.
Fixed prices in Goose Green
Dual RCD board
6 way, from£425- Ideal for 1 to 2 bed flats
- 10 way from £495
- Surge protection included
High integrity
12 way, from£575- 3 to 4 bed houses
- Critical circuits isolated
- Surge protection included
Full RCBO board
8 way, from£625- 10 to 12 way from £695
- 14 to 16 way from £795
- Our recommendation
RCBO + AFDD
10 way, from£1,095- 14 way from £1,295
- HMOs & period terraces
- Selected circuits from £845
No travel charge to Goose Green. Full breakdown on the pricing page.
Asked in Goose Green
Call for a straight answer from an installer, not a call centre.
Call 0333 360 8691No. They keep charging at the same off peak times, controlled by your meter or timer as before. We reconnect them to correctly rated, protected circuits, check the cables, and make sure the off peak and normal supplies are clearly labelled on the new board, so nobody gets caught out working on them later.
It depends on the system, but a heat pump typically needs one circuit for the outdoor unit and often others for its controls, cylinder or backup immersion. Where a house is heading that way, our usual suggestion is a full RCBO board with 10 to 12 ways at £695, which also leaves room for an EV charger later.
If anything outside is fed from your main board, such as a garage, stable or workshop, yes. We need to test those circuits at both ends to certify the new board. Tell us what is out there when you send your photos, and we include it in the fixed price.
Also covering places near Goose Green
Book your Goose Green fuse box replacement
Thinking about a heat pump, or living with storage heaters? Reach us by text on 0333 360 8691 with pictures of the consumer unit and meter, and we will set a fixed Goose Green price.
- Call, 8am to 8pm0333 360 8691
- CoverageGoose Green (Thakeham): RH20