Crowborough sits high on the edge of Ashdown Forest, and much of its housing is large and detached, often with garages, annexes and outbuildings fed from the main house. That means bigger boards and more to test. We replace fuse boxes at fixed prices, with surge protection and full certification.

  • Part P registered installers
  • Fitted and certified in a day
  • Surge protection as standard
  • Fixed prices, no surprises
  • 17+ YearsEst. 2009 in Brighton & Hove
  • 6 Year GuaranteeWorkmanship, every board
  • Specialist TeamDirectly employed installers
  • Free QuotationSurvey or photo, no call out fee
  • 2,400+Boards replaced since 2009
What we do in Crowborough

Fuse box replacement options in Crowborough

Larger Crowborough homes often need 14 to 16 ways. Every option below is a fixed price that includes Type 2 surge protection, a whole property test and Building Control notification.

Full RCBO consumer unit with surge protection, neatly wired and labelled in a Sussex home
Our standard installationFull RCBO board with surge protection
Crowborough homes

Big houses, big boards

Crowborough grew in the late Victorian and Edwardian period as a healthy hilltop retreat, and many large detached houses from that era still stand in the leafier roads towards the Beacon and the forest. Later decades added more detached and semi-detached homes, while estates around Jarvis Brook and the south of the town brought more modest family houses and bungalows, many of them now extended.

In a large house it is common to find several boards: an original one, another added for a kitchen extension and a third in a garage or annexe. Bringing these together, or replacing them with properly coordinated units, makes the installation safer and easier to manage. A 14 to 16 way RCBO board at £795 suits many of these homes.

  • Large detached houses
  • Several boards rationalised
  • Kitchen extension circuits
  • Garages and annexes
  • 14 to 16 way RCBO boards
  • Whole property certificate
Flush mounted consumer unit mid installation with RCBOs, surge protection and neatly dressed cables
C1 & C2 defects clearedPaperwork to your agent within 48 hours
Renting in Crowborough

Family lets and annexes

Crowborough's rental market leans towards family houses rather than shared housing, with tenants drawn by the schools, the forest and the commute to Tunbridge Wells by road and to London by train from the station at Jarvis Brook. Some owners let out annexes or converted outbuildings separately, which raises its own questions about how those spaces are supplied, metered and protected.

If you let a whole house or an annexe, the private rented sector rules require an EICR at least every five years. Standalone reports cost £175 to £350, or £99 alongside a board change. Where an annexe is fed from the main house, we test the sub-main and its protection as part of the inspection.

  • Family house lets
  • Annexes let separately
  • Sub-mains tested
  • EICR from £175
  • £99 EICR with a new board
  • Clear reports for agents
Large distribution board being installed with cable tray and busbar, levelled and ready for termination
Specified for CrowboroughOutbuildings and sub-mains
Outbuildings and sub-mains

Power beyond the main house

Garden offices, garages and workshops are a regular feature of Crowborough's larger plots. Each is usually supplied by a sub-main cable from the house, and those cables were not always sized or protected correctly when they went in. Some run underground with no record of the route, and a few still feed small boards with rewirable fuses at the far end.

When we replace the main consumer unit, the outgoing way to each outbuilding is fitted with suitable protection, and the sub-main is tested along with the board it feeds. If an outbuilding should have its own earthing arrangement, we explain why and what that involves before any work goes ahead.

  • Garden office supplies
  • Garage and workshop boards
  • Sub-main cables tested
  • Correct protection at the house
  • Remote boards replaced too
  • Outbuilding earthing reviewed
Getting to you

Same day cover in Crowborough

Crowborough is at the northern edge of our area, reached from Brighton through Uckfield on the A26. If your power is out, a board is overheating or there is a burning smell near the fuse box, call us between 8am and 8pm, any day. We will aim to get an installer to you the same day where possible, and in the meantime we can talk you through switching off safely.

Bigger houses take longer, so for a large board change we may plan a full day rather than the usual 4 to 6 hours. We tell you at the quote stage, so nothing comes as a surprise on the day.

Crowborough at a glance

  • PostcodesTN6
  • Typical homesLarge detached houses, family semis
  • CouncilWealden District Council
  • Common board issueMultiple boards and old outbuilding feeds
  • Earthing we seeTN-C-S in town, TT on forest edge homes
  • Getting to youUp the A26 via Uckfield
How long does it take?

A new consumer unit, fitted in a day

  1. 01
    The first hour

    Protect, isolate, strip out

  2. 02
    Hours two to four

    Fit and terminate the new board

  3. 03
    Hour five

    Test every single circuit

  4. 04
    The final hour

    Energise, label, walk through

Not sure how many ways your board needs?

Text a photo of your current fuse box to 0333 360 8691 and we will tell you, with a fixed price, today.

Send a photo
Pricing guide

Fixed fuse box prices in Crowborough

The same published prices we charge everywhere in Sussex, no travel supplement. Every figure includes the board, a Type 2 surge protection device, full testing, your certificate and Part P notification.

Dual RCD board

6 way, from£425

Two RCDs each covering a bank of MCBs. The budget friendly route to full RCD protection for flats and smaller homes.

  • Ideal for 1 to 2 bed flats
  • 10 way from £495
  • Surge protection included
Get a quote

High integrity

12 way, from£575

Dual RCD protection plus dedicated RCBO ways for freezers, alarms and smart home kit, so the circuits that matter never share a trip.

  • 3 to 4 bed houses
  • Critical circuits isolated
  • Surge protection included
Get a quote
Most popular

Full RCBO board

8 way, from£625

One RCBO per circuit. A fault trips only that circuit, fault finding is faster and nuisance tripping all but disappears. Our recommendation.

  • 10 to 12 way from £695
  • 14 to 16 way from £795
  • Our recommendation
Book a survey

RCBO + AFDD

10 way, from£1,095

RCBOs plus arc fault detection devices for the highest level of fire protection available. The right choice for HMOs and period property.

  • 14 way from £1,295
  • HMOs & period terraces
  • Selected circuits from £845
Get a quote
Surge protection retrofit £165 Relocation with a new board add £250 Standalone relocation £395 EICR with any board £99 Standalone EICR £175 to £350

Full breakdown by number of ways on the pricing page.

Where we work in Crowborough

Crowborough and nearby villages

We cover the whole of Crowborough, from the town centre and Crowborough Beacon to Jarvis Brook, St Johns and the roads running out to the forest, plus TN6 villages such as Rotherfield and Mark Cross. Rural addresses and forest edge homes are welcome.

Phones answered 8am to 8pm, 7 daysInstallation slots typically 3 to 5 working days out
TN6In town

Town centre, Crowborough Beacon, Jarvis Brook, St Johns, Poundfield, Steel Cross

TN6Out to the villages

Rotherfield, Mark Cross, Boarshead, Crowborough Warren, Town Row

Crowborough town centre Crowborough Beacon Jarvis Brook St Johns Poundfield Steel Cross Crowborough Warren Boarshead Rotherfield Mark Cross Town Row Ashdown Forest
Crowborough questions

Fuse box questions from Crowborough

Still not sure?

Call for a straight answer from an installer, not a call centre. No pressure, no hard sell.

Call 0333 360 8691

Yes. We price each board on its own, or work out whether some can be combined into one larger unit. Often the main house board is replaced with an RCBO unit, and smaller boards in a garage or annexe are replaced or brought back to the house where that makes sense. A photo of each board, with a note of where it is, lets us give a fixed price.

Not a problem, but it often means a TT earthing system, where the property relies on its own earth electrode. RCD protection is essential on TT systems, and we test the electrode resistance as part of the job. If the reading is poor, we tell you before connecting the new board and explain how it can be improved.

For many homes, yes. Our 14 to 16 way RCBO board is £795 and covers most detached houses with an extension or two. Very large properties, or those with several separate outbuilding feeds, may need more ways or a second board. We count the circuits from your photos and our testing, and tell you plainly if one board will not do.

Yes, both are in our area, as are Boarshead, Town Row and the other villages around Crowborough. Older village cottages can have rewirable fuse boxes and mixed wiring, so the full test that comes with every board change is especially useful there. Prices are the same as in town, with no extra charge for travel.

Not while the main board is being swapped, as the supply to the whole property is off for part of the day. What we can do is tell you in advance when that will be, so you can plan calls and work around it. The garden office circuit is reconnected and tested as soon as the new board is in.

Ready when you are

Price your Crowborough board change

Text photos of every fuse box in the property, including any in garages or annexes, to 0333 360 8691. We will reply with a fixed price for the whole job.

Request a free quote

No obligation, no call out fee. We reply the same day.