Full AFDD boards from £1,095

AFDD Consumer Units in Sussex

An arc fault detection device listens to every circuit for the electrical signature of arcing: a damaged cable, a chewed patch of insulation, a loose terminal, a flex crushed behind the sofa. It disconnects in a fraction of a second, before the arc becomes a fire. We fit AFDD consumer units across East and West Sussex, fully tested, certified and notified under Part P.

Modern RCBO consumer unit in a Sussex home, the same enclosure our AFDD boards use

AFDDs fit the same tidy enclosure as this RCBO board

The service

The fire your fuse box cannot see coming

Almost every electrical fire starts the same way: not with a bang, but with a tiny, persistent arc. A cable nicked by a picture hook in a seaside Victorian terrace, insulation nibbled by mice under a village cottage floor, a terminal that worked loose a decade ago, a flex flattened behind a wardrobe. The arc chars its surroundings a little more every day, and nothing in an ordinary fuse board reacts, because hidden wiring damage like this draws perfectly normal current.

An AFDD, or arc fault detection device, is the answer. It samples the current waveform thousands of times a second and recognises the ragged, high frequency signature of a dangerous arc, then disconnects the circuit before smouldering turns to flame. Amendment 2 of BS 7671 recommends AFDDs on socket circuits in HMOs, high rise buildings and homes with a sleeping risk, which describes a great many homes across Sussex.

We build arc fault detection into full consumer unit replacements, or concentrate it on the circuits that need it most. Either way the job is fixed price, takes a day, and every board includes a Type 2 surge protection device, full testing, an Electrical Installation Certificate and Part P notification.

  • Guide priceFull RCBO and AFDD board from £1,095
  • Selected circuitsAFDD on bedroom and socket circuits from £845
  • Time on site4 to 6 hours for most Sussex homes
  • Power off forAround 4 to 5 hours of the visit
  • CertificationEIC issued, Part P notified to Building Control
  • Guarantee6 years on workmanship, manufacturer warranty on the board

Wondering what it would cost?

Text a photo of your board for a same day AFDD price.

Send a photo
Job photo

An AFDD consumer unit in a Sussex home

One photo from this kind of job in Sussex, showing an AFDD board fitted, tested and labelled.

Safety aspects

What arc fault detection actually protects you from

This is the electrical fire prevention case in plain English. Arcing is the fault your existing protection was never designed to notice, and here is exactly where an AFDD steps in.

  1. Arcs behind plaster are invisible until smoke A failing joint can arc inside a wall for months with nothing to see from the room. An AFDD recognises the distinctive waveform signature of that arc within seconds and disconnects the circuit while it is still a scorch mark, not a fire.
  2. It sees what RCDs and MCBs cannot A series arc across a broken conductor draws normal current and leaks nothing to earth, so the breaker and the RCD both stay closed while it burns. Arc fault detection is the only device in the board that reacts to it.
  3. Sleeping above unknown wiring In HMOs and student lets across Sussex, tenants sleep over circuits nobody has seen in decades. Amendment 2 of BS 7671 recommends AFDDs on socket circuits precisely because a fire at night gives no warning.
  4. Period property, period cable Victorian and Edwardian terraces in the coastal towns and old cottages in the villages carry long hidden runs of aged cable, sometimes nibbled by rodents under the floors, and salt air corrodes terminals in homes all along the Sussex coast. This is exactly the hidden wiring damage AFDDs exist to catch.
  5. Three protections in one device A combined RCBO and AFDD stacks shock protection, overload protection and arc fault detection in a single module, so every circuit it covers is guarded against electrocution, overheating and fire at the same time.
  6. It checks itself, and we check it Every AFDD runs a continuous self test and flags any internal fault on the device. We verify each one on handover, record the results on your certificate, and show you what the indicators mean before we leave.
Why here

Built for Sussex housing stock

Arc fault protection makes sense anywhere, but Sussex homes stack up plenty of the risk factors: old walls, hidden cable runs, busy rental housing, rodents in rural lofts and a salty wind off the sea. These are the homes where we recommend an AFDD consumer unit first.

  • Victorian and Edwardian terraces and Regency conversions in the coastal towns, from Worthing to Eastbourne and Hastings, where cable runs predate everyone living above them
  • HMOs and student lets across the county, where occupants sleep over wiring nobody has inspected
  • Seafront and clifftop homes along the Sussex coast, where salt air corrodes accessories and terminations
  • Lofts, cellars and underfloor voids with any history of mice or rats, from village cottages to farmhouses in the Weald and on the Downs
  • Rooms where heavy furniture sits on flexes and extension leads chain together
  • Any home where bedrooms sit above circuits you have never seen
Board options

AFDD consumer unit cost

RCBO and AFDD board, 10 ways

from £1,095

Combined RCBO and AFDD modules on every circuit. Shock, overload and arc fault protection together, sized for most Sussex flats and smaller houses.

RCBO and AFDD board, 14 ways

from £1,295

The same protection with room to grow, for larger period houses, farmhouses and barn conversions, extensions and future circuits such as an EV charger.

AFDD on selected circuits

from £845

A full RCBO board with arc fault detection concentrated on bedroom and socket circuits, where the fire risk actually lives. A sensible middle step for newer homes.

Every option includes a Type 2 surge protection device, full testing, an Electrical Installation Certificate and Part P notification to Building Control.

How it works

From first call to certificate

Step
01

Photo or survey, then a fixed price

Text us a photo of your current board and your postcode for a same day AFDD price, or book a free survey anywhere in Sussex, evenings included.

Step
02

Booked within the week

Most AFDD installations are scheduled 3 to 5 working days out. We confirm the arrival window the night before and text when we are on the way.

Step
03

Fitted and tested in a day

Old board out, new board in, typically 4 to 6 hours on site with power off for 4 to 5. We test every circuit and verify every AFDD self test before handover.

Step
04

Certified and notified

Your Electrical Installation Certificate arrives by email within 48 hours and we notify Building Control under Part P. Nothing left hanging.

Read the warnings

Warning signs your fuse box gives before a fire

Electrical fires rarely arrive without notice. A fuse box buzzing or crackling behind its cover is usually a loose terminal arcing thousands of times a minute. A fuse box getting hot to the touch is pushing current through a connection that resists it, and resistance is heat. And if your fuse box smells of burning, hot plastic, fish, or something sharp and acrid, insulation is already cooking somewhere inside. These are not quirks to live with. They are the last warnings a board gives.

Any of these signs, and certainly a fuse box sparking or showing scorch marks, is an emergency rather than a maintenance job. Switch off at the main switch if you can do so safely, keep the cover closed, and call us on 0333 360 8691. We answer 8am to 8pm, 7 days, and we aim to reach emergencies the same day anywhere in Sussex.

The uncomfortable truth is that these are only the faults loud enough for human senses. For every fuse box overheating visibly, others arc away in silence inside walls and floors, with no smell, no sound and no warmth where a hand could find it. That is the gap an AFDD closes: it recognises the electrical signature of an arc long before your ears or nose could, and disconnects the circuit while the damage is still invisible. Fixing the symptom is urgent. An AFDD board is the permanent protection.

Symptom checklist

Look, listen and smell

  • Buzzing, humming or crackling from the board, especially a noise that comes and goes with one appliance
  • A smell of burning around the unit: hot plastic, a fishy odour or an acrid edge to the air
  • A case, breaker or fuse carrier that feels warm or hot to the touch
  • Scorch marks or brown staining around fuses, breakers or cable entries
  • Sparks, flashes or pops from inside or around the unit
  • Melted, softened or distorted plastic anywhere on the board
  • Breakers that trip again the moment they are reset, or fuses that blow repeatedly

Seeing these signs right now?

Emergencies reached the same day across Sussex where we can, 45 to 90 minutes in Brighton & Hove.

Call 0333 360 8691
Straight answers

AFDD consumer unit FAQs

In most owner occupied homes, no. Amendment 2 of BS 7671 recommends arc fault detection devices on socket circuits in HMOs, high rise buildings and other homes with a sleeping risk, and building types like student accommodation are treated more strictly. For an ordinary Sussex house they are a recommendation rather than a rule, in the same way smoke alarms once were. For an HMO or student let anywhere in Sussex we think the case is strong enough that we always raise it, and many local landlords now specify AFDDs at every board change.

Far less than their early reputation suggests. Normal household arcs from drill motors, vacuum cleaners and light switches have a recognisable pattern, and a modern AFDD compares what it hears against the signature of a dangerous arc before it acts. When one of our customers reports repeat tripping, the device has usually found something real: we have traced trips to a nail through a cable and a flattened flex under a bed in a flat. If a device ever does misbehave, we investigate under the 6 year workmanship guarantee rather than leaving you to live with it.

The risk is lower in newer wiring, but it never reaches zero. Arc faults come from life as much as age: a screw through a cable during shelf fitting, a flex crushed behind a sofa, insulation chewed by mice in a loft. In a newer home, such as those on the new build estates around Burgess Hill, Horsham or Chichester, we would usually suggest arc fault detection on bedroom and socket circuits, which starts at £845, rather than the full board. In a period property, or anywhere people sleep in rooms above old wiring, the full RCBO and AFDD board from £1,095 is the option we would pick for our own families.

Socket circuits first, because that is where flexes get crushed behind furniture, plugs work loose and extension leads chain together. Circuits serving bedrooms matter most of all, since a fire that starts while people sleep spreads before anyone smells it. Long cable runs through the floors and voids of Victorian terraces in the coastal towns and of older village cottages are also prime candidates, as is anything feeding an HMO letting room. Fixed lighting circuits carry the least risk, which is why our selected circuit option concentrates arc fault detection where it earns its keep.

Treat it seriously. A healthy consumer unit is silent, so a fuse box making noise, whether a buzz, a hum or a crackle, usually means a loose connection arcing behind the cover, and arcing is how most electrical fires begin. Do not open the board to investigate. Call us on 0333 360 8691, we answer 8am to 8pm, 7 days a week, and we reach emergencies the same day across Sussex wherever we can.

Turn the installation off at the main switch if you can reach it safely, leave the cover alone, and call us straight away on 0333 360 8691. A burning smell from a fuse box, often hot plastic or an oddly fishy odour, means insulation is overheating at that moment, not at some point in the future. We treat it as an emergency and aim to be on site the same day anywhere in Sussex.

Mild warmth near a heavily loaded circuit can be normal, but a consumer unit overheating, with a case or breaker that is uncomfortable to touch, points to a loose or corroded connection resisting the current passing through it. Resistance makes heat, heat loosens terminals further, and left alone the cycle ends in a burnt fuse box. Switch off what you can, call us, and we will inspect it. A fuse box getting hot has never once fixed itself.

Replacement, almost always. Heat fierce enough to leave a burnt or melted fuse box has usually damaged the busbar, the terminals and the enclosure itself, and no honest electrician can certify that as safe again. A damaged fuse box is also evidence that its connections were failing, so we fit a new board, test every circuit and issue an Electrical Installation Certificate with Part P notification. Dual RCD replacements start from £425 if budget is tight, and every board includes a Type 2 surge protection device.

AFDD boards near you

AFDD consumer units for every Sussex home

Arc fault protection is available wherever we work, which is everywhere below. Each location has its own page with detail about the local housing.

826 places

Villages, hamlets and neighbourhoods 775 places, by council area

Adur 5 places
Arun 57 places
Chichester District 173 places
Crawley 18 places
Horsham District 120 places
Mid Sussex 57 places
Worthing 1 place
Lewes District 56 places
Rother 103 places
Wealden 185 places
Fixed price today

Add arc fault protection this week

Call for a straight answer on AFDDs, or send a photo of your current board and get a fixed price back the same day, anywhere in Sussex.