
Fuse Box Replacement in West Burton
Bury parish includes the small village of West Burton, at the foot of the Downs near Bignor and a few miles north of Arundel. Our own installers, who hold Part P registration, will replace an old fuse box here at a fixed price, boards feeding annexes and outbuildings included, and the travel is free.
- Part P registered installers
- Fitted and certified in a day
- Surge protection as standard
- Fixed prices, no surprises
- 17+ YearsEst. 2009 in Brighton & Hove
- 6 Year GuaranteeWorkmanship, every board
- Specialist TeamDirectly employed installers
- Free QuotationSurvey or photo, no call out fee
- 2,400+Boards replaced since 2009
Fuse box services for West Burton
RCBO Consumer Units
AFDD Consumer Units
Surge Protection
Fuse Box Relocation
Landlord Fuse Box Upgrades
EICR Testing
Transparent Pricing
Free Fixed Quotes

Older homes that have grown over time
West Burton is a quiet village of mainly older properties, many of them altered over the decades as kitchens, bathrooms and extra rooms were added. Each change tended to put more circuits onto whatever board was already there, so the fuse box can end up crowded, unlabelled and carrying far more than it was ever designed for.
A replacement gives you one clear consumer unit with a written circuit schedule. We trace and label each circuit, test insulation and earthing throughout, and point out anything worth fixing. Prices start at £425 for a dual RCD board and £625 for full RCBO protection.
- Crowded boards rationalised
- Circuits traced and labelled
- Insulation and earthing tested
- Written schedule left on the board

When the power runs beyond the house
Country homes often supply more than the house itself: a garage, a workshop, a garden studio, a granny annexe or stables. Older outbuilding supplies were sometimes run in cable never meant to be buried, or simply spurred off a socket circuit, and they are often the hidden reason a new RCD keeps tripping after a board change.
We check each outbuilding feed when the board is changed and protect it correctly at the main consumer unit. Where an annexe has its own small board, we make sure the two work together so a fault out in the annexe does not cut power to the main house.
- Outbuilding cables inspected
- Sub mains protected correctly
- Annexe boards coordinated
- Fixed price for any remedial work
Travelling to West Burton
Tucked just off the A29 beyond Bury, West Burton is reached along the A27 and north through Arundel, at no charge for the journey. Quotes are fixed, and a texted photo is enough to produce one. A complete loss of power calls for a phone call instead, and our aim then is to be out the same day.
West Burton at a glance
- ParishBury
- CouncilChichester District Council
- PostcodeRH20
- Nearest townArundel, 7 km south
- Worth checkingFeeds to annexes and outbuildings
A new consumer unit, fitted in a day
- 01The first hour
Protect, isolate, strip out
- 02Hours two to four
Fit and terminate the new board
- 03Hour five
Test every single circuit
- 04The final hour
Energise, label, walk through
Not sure how many ways your board needs?
Text a photo of your current fuse box to 0333 360 8691 and we will tell you, with a fixed price, today.
Fixed prices in West Burton
Dual RCD board
6 way, from£425- Ideal for 1 to 2 bed flats
- 10 way from £495
- Surge protection included
High integrity
12 way, from£575- 3 to 4 bed houses
- Critical circuits isolated
- Surge protection included
Full RCBO board
8 way, from£625- 10 to 12 way from £695
- 14 to 16 way from £795
- Our recommendation
RCBO + AFDD
10 way, from£1,095- 14 way from £1,295
- HMOs & period terraces
- Selected circuits from £845
No travel charge to West Burton. Full breakdown on the pricing page.
Asked in West Burton
Call for a straight answer from an installer, not a call centre.
Call 0333 360 8691Usually because of a fault the old fuse box could never detect: damp in an outside junction box, a damaged buried cable, or a neutral shared with another circuit. A modern RCD reacts to tiny leakage currents. We find the cause during testing and fix it properly rather than hiding it with a less sensitive device.
Yes, and that is often the best arrangement. The annexe board is fed from a properly protected way in the main consumer unit, and we set up the protection so that a fault in the annexe trips locally first. If the annexe board is old as well, we can replace both at the same visit.
Enough for every existing circuit plus a few spares. We count your circuits during the survey, then allow room for things you may add later, such as an outside socket, an EV charger or a heat pump. A board with spare ways costs little more now and saves a second change in a few years.
Also covering places near West Burton
Book your West Burton fuse box replacement
From a cramped old fuse box to the feed for your studio, the photo you text message to 0333 360 8691 is what we base a fixed West Burton price on.
- Call, 8am to 8pm0333 360 8691
- CoverageWest Burton: RH20