Fuse Box Replacement in Edburton
Close to Brighton, Edburton is a scattered hamlet on the lane along the foot of the Downs between Upper Beeding and Fulking, east of Steyning. Each new board fitted here is priced at a fixed figure and followed by a full test of every circuit, the earthing that rural homes rely on included.
- Part P registered installers
- Fitted and certified in a day
- Surge protection as standard
- Fixed prices, no surprises
- 17+ YearsEst. 2009 in Brighton & Hove
- 6 Year GuaranteeWorkmanship, every board
- Specialist TeamDirectly employed installers
- Free QuotationSurvey or photo, no call out fee
- 2,400+Boards replaced since 2009
Fuse box services for Edburton
RCBO Consumer Units
AFDD Consumer Units
Surge Protection
Fuse Box Relocation
Landlord Fuse Box Upgrades
EICR Testing
Transparent Pricing
Free Fixed Quotes

Isolated homes, wiring from several decades
In the truest sense a hamlet, Edburton amounts to a church and a loose string of farms and cottages along the lane, with open fields running north towards the Weald. Homes this far out have often been modernised a room at a time, so wiring from several decades can end up on one installation, with old fuses for some circuits and a newer unit bolted on for others.
Replacing it all with one consumer unit gives every circuit modern protection and a clear label. Testing shows how the older cables are holding up, so you can plan any rewiring on your own timetable rather than finding out after a fault.
- Mixed era wiring brought together
- Circuit schedule left on site
- Insulation of old cables tested
- Honest advice on any rewiring

Rural supplies need a properly tested earth
Out here the supply often comes in on an overhead line strung between wooden poles, and plenty of homes are TT earthed, depending on an earth rod sunk in the ground instead of an earth provided by the network. On a TT supply the RCD is doing essential safety work, so a fuse box lacking one, or a rod that has corroded or been disturbed, is a genuine concern.
Each board change includes a reading of the earth electrode's resistance, plus checks on the main earthing and the bonding to water, oil or gas pipework. If the rod reading is poor we tell you and can fit a new one. Every reading is written onto your certificate, which we email across within 48 hours.
- Earth electrode resistance measured
- Main bonding checked and upgraded
- RCD protection on every circuit
- Readings recorded on your certificate
The quickest way to Edburton
Few rural addresses in this corner of the county are closer for us than Edburton. Depending on traffic we come over the Downs through Poynings and Fulking, or up the Adur valley via Upper Beeding. The usual way to book is board photos by text, a fixed price, then a date you pick; if something has already failed, call us.
Edburton at a glance
- ParishUpper Beeding
- CouncilHorsham District Council
- PostcodeBN5
- Hub townSteyning, 5.5 km
- Supply we expectOverhead line, often TT earthed
A new consumer unit, fitted in a day
- 01The first hour
Protect, isolate, strip out
- 02Hours two to four
Fit and terminate the new board
- 03Hour five
Test every single circuit
- 04The final hour
Energise, label, walk through
Not sure how many ways your board needs?
Text a photo of your current fuse box to 0333 360 8691 and we will tell you, with a fixed price, today.
Fixed prices in Edburton
Dual RCD board
6 way, from£425- Ideal for 1 to 2 bed flats
- 10 way from £495
- Surge protection included
High integrity
12 way, from£575- 3 to 4 bed houses
- Critical circuits isolated
- Surge protection included
Full RCBO board
8 way, from£625- 10 to 12 way from £695
- 14 to 16 way from £795
- Our recommendation
RCBO + AFDD
10 way, from£1,095- 14 way from £1,295
- HMOs & period terraces
- Selected circuits from £845
No travel charge to Edburton. Full breakdown on the pricing page.
Asked in Edburton
Call for a straight answer from an installer, not a call centre.
Call 0333 360 8691It is very likely your earthing conductor running to an earth rod outside, which means the property is TT earthed. That is normal for rural homes, but the rod needs testing and the board must have RCD protection. Text us a photo of the meter position and we will confirm what you have before we quote.
Flicker that comes with the weather is usually on the overhead network rather than inside your home, and that is one for UK Power Networks, who you can reach by calling 105. If the flicker happens whatever the weather, or one circuit keeps dropping out, a loose connection in an old board is possible and we can check it.
In most cases, yes. The new board, its RCBOs and its surge protection stay in place when circuits are rewired, so the money is not wasted. Testing at the board change also shows which circuits are sound, which helps you decide whether a full rewire is needed at all or only part of the house.
Also covering places near Edburton
Book your Edburton fuse box replacement
Your Edburton earthing can be confirmed, and the price fixed, from one message to 0333 360 8691 carrying a single shot that shows fuse box and meter position together.
- Call, 8am to 8pm0333 360 8691
- CoverageEdburton: BN5