Fuse Box Replacement in Parkminster
The tall spire of St Hugh's Charterhouse marks Parkminster, a hamlet in Cowfold parish south of Horsham. Its homes are few and spread out. Board changes are fixed price, and we test the earthing on rural supplies as part of every job.
- Part P registered installers
- Fitted and certified in a day
- Surge protection as standard
- Fixed prices, no surprises
- 17+ YearsEst. 2009 in Brighton & Hove
- 6 Year GuaranteeWorkmanship, every board
- Specialist TeamDirectly employed installers
- Free QuotationSurvey or photo, no call out fee
- 2,400+Boards replaced since 2009
Fuse box services for Parkminster
RCBO Consumer Units
AFDD Consumer Units
Surge Protection
Fuse Box Relocation
Landlord Fuse Box Upgrades
EICR Testing
Transparent Pricing
Free Fixed Quotes

What a hamlet's houses tend to need
With only a small number of properties along the road and the lanes nearby, Parkminster has no single type of house. Expect older cottages, farm properties and individual detached homes, each wired in its own way and at its own time. The fuse box we find could be a modern board, a 1990s split load unit or something much older.
That is why we ask for photos first. From one clear shot showing both board and meter, we can usually commit to a figure: £425 upwards for a dual RCD board, or £625 upwards for an RCBO board throughout if you want each circuit to trip on its own.
- Photos give a firm price
- Dual RCD from £425
- Full RCBO from £625
- Older and newer homes alike

TT earthing and the earth rod in your garden
Properties away from village centres are often supplied by overhead lines, and many such homes have no earth provided by the network. Instead, these homes get their earth from a rod sunk into the soil, an arrangement called a TT system. If the rod has corroded, been disturbed or was never very effective, the protection on every circuit suffers.
Each time we change a board here, the rod's resistance to earth is measured and the main earthing conductor checked. On a TT supply, RCD protection is what disconnects a fault quickly, so a board with good RCDs or RCBOs matters even more. If the rod needs replacing, we tell you before we start.
- Earth rod resistance measured
- Main earth conductor checked
- RCD cover suited to TT
- Rod problems raised first
Finding you near Parkminster
To get here from Brighton & Hove we usually head north through Henfield on the A281. Hamlet addresses can be hard to find, so a what3words location or a note about your gate helps. Travel within Sussex is never added to the bill, and a fault reported by phone can often be seen to the same day, diary permitting.
Parkminster at a glance
- ParishCowfold
- CouncilHorsham District Council
- PostcodeRH13
- Nearest townHorsham, 10.2 km to the north
- Supply we expectOften TT, with an earth rod
A new consumer unit, fitted in a day
- 01The first hour
Protect, isolate, strip out
- 02Hours two to four
Fit and terminate the new board
- 03Hour five
Test every single circuit
- 04The final hour
Energise, label, walk through
Not sure how many ways your board needs?
Text a photo of your current fuse box to 0333 360 8691 and we will tell you, with a fixed price, today.
Fixed prices in Parkminster
Dual RCD board
6 way, from£425- Ideal for 1 to 2 bed flats
- 10 way from £495
- Surge protection included
High integrity
12 way, from£575- 3 to 4 bed houses
- Critical circuits isolated
- Surge protection included
Full RCBO board
8 way, from£625- 10 to 12 way from £695
- 14 to 16 way from £795
- Our recommendation
RCBO + AFDD
10 way, from£1,095- 14 way from £1,295
- HMOs & period terraces
- Selected circuits from £845
No travel charge to Parkminster. Full breakdown on the pricing page.
Asked in Parkminster
Call for a straight answer from an installer, not a call centre.
Call 0333 360 8691Look near the meter for a green and yellow cable. If it runs from the main earthing terminal out through the wall or down towards the ground, rather than clamping onto the incoming supply cable, you probably have a TT system with a rod outside. Send us a photo of the meter area and we can usually tell you.
No, it simply shapes the design. On a TT system the earth rod cannot carry enough fault current to operate a fuse or breaker quickly, so RCD protection does that job. We pick the devices to match, test the rod, and record the readings on your certificate, which we email over within 48 hours.
Someone needs to let us in, show us the board and the meter, and be around at the end when we explain the new board. Expect most changes to last between four and six hours. For most of that time the house has no electricity, so charge phones beforehand and plan meals around the gap.
Also covering places near Parkminster
Book your Parkminster fuse box replacement
We can price the work at your Parkminster home, earthing checks included, from two pictures texted to 0333 360 8691: one of the board and one of the meter.
- Call, 8am to 8pm0333 360 8691
- CoverageParkminster: RH13