EICR remedials cleared, tenants safe, agents happy

Landlord Fuse Box Upgrades in Sussex

From student lets and seafront flat conversions to village cottages and farmhouses, Sussex has rented homes of every kind, and the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 give you 28 days to put an unsatisfactory EICR right. The most common C2 on those reports is an old fuse box. We clear the defect, test every circuit, issue the certificates and copy in your letting agent, so the compliance file is complete and your tenants are properly protected.

Landlord consumer unit upgrade in a Sussex rental, labelled and certified

The finished article: labelled, certified, compliant

The service

EICR C2 remedial work, done inside the window

Sussex rents in every shape and size. Student HMOs fill the Victorian and Edwardian terraces of the coastal and university towns, professional lets occupy Regency and Victorian conversions along the seafront, families rent interwar semis, new town homes in Crawley and houses on the new build estates, and inland there are flint cottages in the villages and farmhouses across the Weald and the Downs. Behind a remarkable number of those front doors sits a fuse box that predates the tenants, sometimes by decades.

Since the 2020 Regulations, every rented home in England needs an EICR at least every 5 years, and an unsatisfactory report must be put right within 28 days. An old board with no RCD protection is the classic C2, and it is exactly the kind of EICR C2 remedial work we do every week. Send us the report, whoever produced it, and we will price the remedials free the same day, fit the new board inside your 28 days, and hand back a file your agent, your insurer and the council will all accept. A rental property consumer unit upgrade is usually booked exactly this way: from the report, inside the deadline, without a single wasted visit.

The board itself is no different from the one we would fit for a homeowner. A landlord fusebox replacement is domestic fusebox replacement with the stakes raised: the same 18th Edition unit and the same fixed prices, plus a legal deadline, tenants to look after and a paperwork trail that has to be right. We have built the service around that second half.

We arrange access with tenants directly, work around student timetables and changeovers in towns and villages across East and West Sussex, and email every certificate to you and your agent within 48 hours. If you hold or are applying for an HMO licence from your local council, we make sure the board is a document the inspection will pass, not a question it will raise.

  • Rental boardFull RCBO board from £695 for a typical Sussex let
  • HMO boardRCBO plus AFDD protection from £1,095
  • Remedial quotesFree from your existing unsatisfactory EICR, same day
  • Lead timeInstall slots 3 to 5 working days, well inside the 28
  • PaperworkEIC, EICR and Part P notification, emailed to you and your agent within 48 hours

Holding an unsatisfactory EICR?

Send it over and get a free remedial quote back the same day.

Send the report
Job photo

A landlord fuse box upgrade in Sussex

One photo from this kind of job in Sussex, showing a rental property board brought up to standard and certified.

Safety aspects

Why a rented fuse box carries the highest duty of care

Your tenants live with whatever protection the board provides, and they had no say in choosing it. Here is what a proper landlord upgrade actually protects, in plain English.

  1. Tenants cannot choose their fuse box They rent the home, not the wiring, and the duty of care sits squarely with the landlord. A tenant in a rented flat has no control over the board in the hallway cupboard, which is exactly why the 2020 Regulations exist. A modern board is how that duty is discharged, not a favour.
  2. 30mA RCD protection where it saves lives Every socket circuit and every bathroom circuit needs RCD protection that disconnects in milliseconds when current flows through a person. That is the difference between a tenant getting a fright from a faulty kettle in a student house share and a fatality you carry for the rest of your life.
  3. HMOs multiply every risk More occupants means more appliances, cooking on every floor, extension leads behind beds and people sleeping above wiring nobody has inspected in years. Amendment 2 of the 18th Edition recommends AFDDs for HMOs precisely because fire risk scales with occupancy, which is why our HMO board includes arc fault detection.
  4. Labelling tenants and trades can follow Every board we fit carries a typed circuit chart with every way labelled, so a student resetting a trip at midnight in a shared house, or a plumber isolating the bathroom, is never guessing which switch controls what. Guesswork at a fuse box is where accidents start.
  5. Documentation that stands up An Electrical Installation Certificate for the new board, a fresh EICR, and Part P notification to Building Control, all filed with you and your letting agent. If the council, your insurer or a deposit dispute ever asks, the answer is already in writing.
  6. Nothing signed off untested We never sign off remedial work we have not tested ourselves. Every circuit is dead tested and live tested by Level 3 qualified engineers before any certificate is issued, because a signature on a landlord's compliance paperwork is a personal guarantee, not a formality.
What's included

Everything a landlord's file needs

  • Free remedial quote from your existing unsatisfactory EICR
  • Access arranged directly with your tenants and letting agent
  • 18th Edition metal consumer unit sized for the property
  • Full RCBO protection, with AFDDs for HMOs and student lets
  • Type 2 surge protection device as standard, not an extra
  • Main bonding to gas and water verified and upgraded where needed
  • Every circuit dead tested and live tested, results recorded
  • Typed circuit chart fitted to the board, every way labelled
  • EIC and fresh EICR emailed to you and your agent within 48 hours
  • Part P notification to your local council's Building Control
Landlord pricing

Fixed prices, no tenant surprises

Full RCBO rental board

from £695

10 to 12 ways, the right size for a typical Sussex rental. One protective device per circuit, so a fault in one room never blacks out the whole let. Smaller flats from £625 for 8 ways.

RCBO plus AFDD HMO board

from £1,095

Arc fault detection on top of full RCBO protection, the specification Amendment 2 recommends for HMOs. 10 ways from £1,095, larger HMOs 14 ways from £1,295. AFDDs explained.

EICR alongside any upgrade

£99 standalone from £175

A fresh landlord electrical safety certificate issued on the same visit as the new board, restarting the five year clock. Remedial quotes from your existing report are always free.

How it works

From unsatisfactory report to complete file

Step
01

Send the report, get a free quote

Email or WhatsApp your unsatisfactory EICR, or a photo of the board and the postcode, and we price the remedials free the same day. Phones answered 8am to 8pm, 7 days.

Step
02

We arrange access, not you

Give us your tenants' numbers and your agent's details. We book a slot around tenants' timetables anywhere in East or West Sussex, usually 3 to 5 working days out, and text before we arrive.

Step
03

Fitted, tested and certified in a day

The upgrade takes 4 to 6 hours with power off for around 4 to 5, so tenants are inconvenienced once, not repeatedly. Every circuit is tested and the fresh EICR is done on the same visit.

Step
04

Certificates to you and your agent

The EIC, the new EICR and confirmation of Part P notification arrive by email within 48 hours, copied to your letting agent so the compliance file closes without a single chasing phone call.

Straight answers

Landlord fuse box FAQs

A C2 means potentially dangerous, and under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 it makes the whole report unsatisfactory. You must complete the remedial work within 28 days of the inspection, or sooner if the report says so, then give written confirmation of the work to your tenants and, if they request it, the council. Send us the report and we will quote the remedials free the same day, fit the new board inside the window, and issue the certificates that close the file.

The wiring regulations are the same, but the risk profile is not, and HMO electrical requirements come under real scrutiny when your local council inspects for an HMO licence. More occupants means more appliances, cooking on several floors and people sleeping above circuits nobody has looked at in years. For student HMOs and shared houses across Sussex we recommend a full RCBO board as the minimum, and Amendment 2 of the 18th Edition specifically recommends AFDDs for HMOs, which is why our HMO board pairs RCBOs with arc fault detection.

Yes, and most of the landlords we work for prefer it. Give us the agent's details and your tenants' numbers and we handle the rest: access arranged around tenants' timetables, a text before we arrive, and the property left tidy. When the work is done, the Electrical Installation Certificate and the fresh EICR go to you and your agent in the same email within 48 hours, so the compliance file is complete without you chasing anyone.

Almost always. A fuse box upgrade takes 4 to 6 hours, and because we test every circuit as part of the installation, we can issue a fresh EICR for £99 on the same visit alongside the Electrical Installation Certificate for the new board. One appointment, one day of disruption for your tenants, and a landlord electrical safety certificate that restarts the five year clock.

Yes, an HMO consumer unit upgrade is one of our most common jobs. Licensed HMOs across Sussex come under close scrutiny, so we fit full RCBO boards with AFDD protection, the specification Amendment 2 of the 18th Edition recommends for houses in multiple occupation. 10 ways from £1,095, larger HMOs 14 ways from £1,295, and the certificates a licence inspection will ask to see are emailed to you and your agent within 48 hours.

Both, every week. A flat fusebox replacement often involves a meter in a communal riser, a board in a hallway cupboard and a freeholder or managing agent to keep informed, and we handle all of that as standard in the Regency and Victorian conversions found in the coastal towns across Sussex. A house fusebox replacement is usually more straightforward. Either way the price is fixed before we start: full RCBO boards from £625 for 8 ways in a smaller flat, or from £695 for the 10 to 12 ways a typical house needs.

Yes. Alongside our domestic work we replace small commercial fuseboards for shops, cafes, salons and offices across Sussex. It is the same fixed pricing approach as our domestic side, with full testing and certification, and we schedule the changeover around your trading hours wherever we can. Commercial boards vary far more than domestic ones, so rather than guessing over the phone we quote after a short survey. Call 8am to 8pm, 7 days, to arrange one.

The hardware is not: it is the same 18th Edition metal consumer unit, Type 2 surge protection and full testing we would fit in any domestic consumer unit replacement, at the same fixed prices. What changes is everything around the job: a 28 day deadline if an EICR was unsatisfactory, access arranged with tenants rather than the owner, certificates copied to your letting agent, and a fresh EICR for £99 on the same visit so the five year clock restarts.

Every kind of property

Access, keys and tenants, handled properly

The wiring is the easy half of working in rented property. The harder half is getting into someone's home without souring the tenancy, and that side of the job is routine for us. Tell us who holds the keys and we take it from there.

Flats and maisonettes

A flat fusebox replacement usually happens inside a shared building, so we look after the block as well as the flat: dust sheets down in the communal hallway, fire doors kept shut, tools and packaging kept inside the property, and everything swept before we leave. The neighbours should barely know we were there.

Occupied houses and HMOs

Tenants get proper notice: a date agreed in advance, an arrival window they have said yes to, and a message when we are on the way, so nobody opens the door to a stranger. For a house fusebox replacement in an occupied let, or a full student house share, we agree the power-off with whoever is home that day and give fair warning before the supply goes off.

Empty properties and commercial premises

A gap between tenancies is the ideal slot: we collect the keys from you or the letting agent, fit and test the new board while the property stands empty, and drop the keys back the same day. The same thinking applies to a commercial consumer unit upgrade in a shop or cafe, where an early start means the power is back on before the doors open.

Landlords across Sussex

Landlord upgrades in every Sussex location

Lets in towns, villages and holiday hamlets all fall under the same Electrical Safety Standards. These are the places we cover for landlords and agents.

826 places

Villages, hamlets and neighbourhoods 775 places, by council area

Adur 5 places
Arun 57 places
Chichester District 173 places
Crawley 18 places
Horsham District 120 places
Mid Sussex 57 places
Worthing 1 place
Lewes District 56 places
Rother 103 places
Wealden 185 places
The 28 day clock is ticking

Clear that C2 before the deadline

Send your unsatisfactory EICR today for a free remedial quote, or call for a straight answer on any Sussex rental or HMO board.