Small hamlet, rural supply

Fuse Box Replacement in Nyton

Nyton is one of several small settlements that make up Aldingbourne parish, lying close to Westergate and north of Felpham. Out here a fuse box change is as much about the supply and earthing as the board itself, so we check both before fitting a new metal consumer unit.

  • Part P registered installers
  • Fitted and certified in a day
  • Surge protection as standard
  • Fixed prices, no surprises
  • 17+ YearsEst. 2009 in Brighton & Hove
  • 6 Year GuaranteeWorkmanship, every board
  • Specialist TeamDirectly employed installers
  • Free QuotationSurvey or photo, no call out fee
  • 2,400+Boards replaced since 2009
What we do in Nyton

Fuse box services for Nyton

Full RCBO consumer unit with surge protection, neatly wired and labelled in a Sussex home
Our standard installationFull RCBO board with surge protection
A hamlet's houses

Country homes with their own quirks

With only a small number of homes, Nyton has no single type of house. Expect individual properties in their own plots, some extended, some with outbuildings, each with a board that reflects its own history. So before we quote, it really helps to see pictures of the fuse box, the meter and the supply cable coming into the house.

From those photos we can usually see the earthing arrangement, the main fuse and how many circuits you have. Most homes of this kind need 6 to 10 ways, priced from £425 for dual RCD, with RCBO boards from £625 if you would like each circuit protected separately.

  • Photo of meter and supply cable
  • Earthing type identified
  • Circuits counted before quoting
  • Dual RCD or RCBO, your choice
Large distribution board being installed with cable tray and busbar, levelled and ready for termination
Specified for NytonOverhead lines and earth rods
Overhead lines and earth rods

TT earthing on rural supplies

Away from the main roads, some homes take their supply from overhead lines, and if UK Power Networks provides no earth terminal, the house depends on its own earth rod sunk into the soil. This is a TT system. It is safe only if the rod is in good condition and every circuit is protected by an RCD that will disconnect quickly when a fault occurs.

At each TT property we take a reading of the earth electrode's resistance, inspect the rod and its connection, and pick a board layout to suit, often RCBOs so a single fault cannot black out the whole house. If the rod is missing or failing, we tell you and price a replacement.

  • Earth electrode resistance measured
  • Rod and clamp inspected
  • RCD protection on every circuit
  • Overhead service checked by eye
Getting to you

On our way to Nyton

From Brighton & Hove we head west on the A27, turn south onto the A29 at Fontwell and are close to the hamlet within minutes, with Felpham further south. Phones are staffed every day, and a dead or overheating board gets same day priority wherever we can manage it.

Nyton at a glance

  • ParishAldingbourne
  • CouncilArun District Council
  • PostcodePO20
  • Nearest town pageFelpham, 5.8 km south
  • Supply we check forTT earth rod or PME
How long does it take?

A new consumer unit, fitted in a day

  1. 01
    The first hour

    Protect, isolate, strip out

  2. 02
    Hours two to four

    Fit and terminate the new board

  3. 03
    Hour five

    Test every single circuit

  4. 04
    The final hour

    Energise, label, walk through

Not sure how many ways your board needs?

Text a photo of your current fuse box to 0333 360 8691 and we will tell you, with a fixed price, today.

Send a photo
Pricing guide

Fixed prices in Nyton

Dual RCD board

6 way, from£425
  • Ideal for 1 to 2 bed flats
  • 10 way from £495
  • Surge protection included
Get a quote

High integrity

12 way, from£575
  • 3 to 4 bed houses
  • Critical circuits isolated
  • Surge protection included
Get a quote
Most popular

Full RCBO board

8 way, from£625
  • 10 to 12 way from £695
  • 14 to 16 way from £795
  • Our recommendation
Book a survey

RCBO + AFDD

10 way, from£1,095
  • 14 way from £1,295
  • HMOs & period terraces
  • Selected circuits from £845
Get a quote
Surge protection retrofit £165 Relocation with a new board add £250 Standalone relocation £395 EICR with any board £99 Standalone EICR £175 to £350

No travel charge to Nyton. Full breakdown on the pricing page.

Nyton questions

Asked in Nyton

Still not sure?

Call for a straight answer from an installer, not a call centre.

Call 0333 360 8691

Start at the meter position. On a TT supply the network cut-out has no earth terminal of its own, and instead a green and yellow conductor heads off through the wall to a rod outside, sometimes under a small inspection cover. A clear photo of that area is usually enough for us to say, and on the day we measure it to be certain.

It might not be. Flicker that follows the wind often points to the overhead supply, which belongs to UK Power Networks and can be reported by calling 105. A loose connection in the board or meter tails can cause flicker too, though, so if the supply checks out, send us a photo and we will look at the house side.

On a TT system the fault path runs back through the ground, which has far higher resistance than a metal conductor. A fault may not draw enough current to blow a fuse or trip a circuit breaker, so it could sit there live. An RCD senses the leakage itself and disconnects within a fraction of a second, which is why every circuit needs one.

Ready when you are

Book your Nyton fuse box replacement

The earthing arrangement usually shows up in pictures of the fuse box and meter: text yours to 0333 360 8691 so we can confirm it and send back a fixed Nyton price.

Request a free quote

No obligation, no call out fee. We reply the same day.